DSH ZP 2 LSG A TT 255, 909231, 909 231, Thiết bị chống sét nguồn điện 3 pha cấp 1 + cấp 2 + cấp 3, Cắt Lọc Sét DEHN, Chống Sét
This product is no longer in stock
Availability date:
DSH ZP 2 LSG A TT 255, 909231, 909 231, Thiết bị chống sét nguồn điện 3 pha cấp 1 + cấp 2 + cấp 3, Cắt Lọc Sét DEHN, Chống Sét
DSH ZP 2 LSG A TT 255, 909231, 909 231, Thiết bị chống sét nguồn điện 3 pha cấp 1 + cấp 2 + cấp 3, Cắt Lọc Sét DEHN, Chống Sét
Recipient :
* Required fields
or Cancel
DSH ZP 2 LSG A TT 255, 909231, 909 231, Thiết bị chống sét nguồn điện 3 pha cấp 1 + cấp 2 + cấp 3, Cắt Lọc Sét DEHN, Chống Sét
https://www.dehn-international.com/store/p/en-DE/F4319368/dehnshield-zp
Download Part No. 909231 DSH ZP 2 LSG A TT 255
GTIN 4013364449756, Customs tariff No.: 85363090, Gross weight: 873.00 g, PU: 1.00 pc(s)
Images
Technical data
SPD according to EN 61643-11 / IEC 61643-11 | type 1 + type 2 + type 3 / class I + class II + class III |
Energy coordination with terminal equipment (≤ 10 m) | type 1 + type 2 + type 3 |
Nominal voltage (a.c.) (UN ) | 230 / 400 V (50 / 60 Hz) |
Max. continuous operating voltage (a.c.) (UC ) | 255 V (50 / 60 Hz) |
Lightning impulse current (10/350 µs) [L1+L2+L3+N-PE] (Itotal ) | 50 kA |
Lightning impulse current (10/350 µs) [L-N] (Iimp ) | 12.5 kA |
Specific energy [L-N] (W/R ) | 39.06 kJ/ohms |
Lightning impulse current (10/350 µs) [N-PE] (Iimp ) | 50 kA |
Specific energy [N-PE] (W/R ) | 625 kJ/Ohm |
Nominal discharge current (8/20 µs) [L-N]/[N-PE] (In ) | 20 / 80 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.5 kV |
Voltage protection level [N-PE] (UP ) | ≤ 1.5 kV |
Open-circuit voltage of the combination wave generator (UOC ) | 20 kV |
Max. mains-side overcurrent protection | 160 A gG |
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic | 440 V / 120 min. – withstand |
Temporary overvoltage (TOV) [N-PE] (UT) – Characteristic | 1200 V / 200 ms – withstand |
Operating temperature range (TU ) | -40 °C ... +80 °C |
Operating state / fault indication | green / red |
Number of ports | 1 |
Cross-sectional area (PEN, 9) | 16-25 mm2 flexible / 16-35 mm2 stranded |
For mounting on | 40 mm busbar systems |
Enclosure material | thermoplastic, red, UL 94 V-0 |
Place of installation | indoor installation |
Degree of protection | IP 30 (in combination with cover) |
Approvals | VDE |
Power supply (for compartment for additional applications/termination point meter mounting board according to VDE-AR-N 4100) (UN ) | 230 V |
Suitable circuit breakers (manufacturer, type) | ABB S201P-B6, Hager MB199 |
Rated current of the circuit breaker (In ) | 6 A |
Tripping characteristic | B |
Extended technical data: | --------------------------------- |
Voltage protection level [L-PE] (UP ) | ≤ 1.6 kV |