SFL PRO6X multiple socket outlet w. integr. surge prot. + mains filter
Six-way socket outlet with integrated surge protection and filter
Type 3 SPD according to EN 61643-11
Interference suppressor filter according to DIN VDE 0565 Part 3
Mains switch with operating state indication: green
Visual fault indication: red
Max. continuous operating voltage: 255 V a.c.
Voltage protection level: <= 1.5 kV
Total discharge current: 5 kA
Max. mains-side overcurrent protection: 16 A gG or B 16 A
Attenuation at f = 1 MHZ balanced/unbalanced >= 32 dB / >= 30 dB
Energy-coordinated according to IEC 62305-4
with arresters of the Red/Line series
delivery and installation.
Brand: DEHN + SÖHNE
Type: SFL PRO 6X
Part No.: 909 250
or equivalent.
Type |
SFL PRO 6X |
Part No. |
909 250 |
SPD according to EN 61643-11 / IEC 61643-11 |
type 3 / class III |
Nominal a.c. voltage (UN) |
230 V (50 / 60 Hz) |
Max. continuous operating voltage (a.c.) (UC) |
255 V (50 / 60 Hz) |
Nominal load current (a.c.) (IL) |
16 A |
Voltage drop in percent for UC/IL (∆U) |
≤ 0.5 % |
Nominal discharge current (8/20 µs) (In) |
3 kA |
Total discharge current (8/20 µs) [L+N-PE] (Itotal) |
5 kA |
Combined wave (UOC) |
6 kV |
Combined wave [L+N-PE] (UOC total) |
10 kV |
Voltage protection level (UP) |
≤ 1.5 kV |
Response time [L-N] (tA) |
≤ 25 ns |
Response time [L/N-PE] (tA) |
≤ 100 ns |
Max. mains-side overcurrent protection |
B 16 A |
Short-circuit withstand capability for max. mains-side overcurrent protection (ISCCR) |
1.5 kArms |
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic |
335 V / 5 sec. – withstand |
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic |
440 V / 120 min. – safe failure |
Temporary overvoltage (TOV) [L/N-PE] (UT) – Characteristic |
335 V / 120 min. – withstand |
Temporary overvoltage (TOV) [L/N-PE] (UT) – Characteristic |
440 V / 5 sec. – withstand |
Temporary overvoltage (TOV) [L+N-PE] (UT) – Characteristic |
1200 V + UREF / 200 ms – safe failure |
Fault indication |
red light |
Operating state indication |
green light |
Number of ports |
2 |
Operating temperature range (TU) |
-20 °C ... +40 °C |
Connecting cable |
approx. 2000 mm |
Number of socket outlets |
6 |
For mounting on |
earthed socket outlets DIN 49440 / DIN 49441 |
Enclosure material |
thermoplastic, black / silver, UL 94 V-1 |
Place of installation |
indoor installation |
Degree of protection |
IP 20 |
Dimensions |
571 x 72 x 43 mm |
Mains filter |
acc. to EN 60393-1 (DIN VDE 0565-3) |
Attenuation for f = 1 MHz, balanced |
≥ 32 dB |
Attenuation for f = 1 MHz, unbalanced |
≥ 30 dB |
Weight |
1,1 kg |
GTIN |
4013364132566 |
PU |
1 pc(s) |
Part No. |
909 250 |