MLP SERIES : MLP

MLP series Type 2 and 3 surge protector for LED outdoor lighting

 

MLP1-230L-W

- Type 2 or 3 surge protector
- For LED lighting system
- Class I 
- Very compact dimensions
- Max. discharge current 10kA
- EN 61643-11, IEC 61643-11 compliance

The MLP range is a comprehensive series of AC surge protectors
dedicated to LED lighting system. Some versions are
equipped with an extra dataline surge protection (RS485 or
DALI) in order to provide a full solution for LED systems with
transmission features. By this way the MLP range is able to provide
all the existing configurations with an efficient solution .
MLP surge protectors are based on a powerful association of
MOV and GDT components, able to protect LED system against
huge surges without disconnection.
In the worse case, the SPD will fail in safety condition. Indication
of the SPD failure is performed through power supply cut off
and/or through remote signaling feature.

Citel model : MLP1-230L-W

Part Number : 711211

Click on the blocks to display detailed characteristics

Electrical characteristics
Hide details
SPD type
follow test IEC 61643-11
  2/3
Network
  220-240 V single-phase
AC system
  TT-TN
Nominal line voltage
Un
230-277 Vac
Max. AC operating voltage L-N
Uc
305 Vac
Temporary Over Voltage (TOV) Charasteristics - 5 sec.
without disconnection
UT
580 Vac withstand
Temporary Over Voltage (TOV) Charasteristics - 120 mn
without disconnection or with safety disconnection
UT
440 Vac disconnection
Residual Current
LeakAge current at Uc
Ipe
none
Follow current
If
none
Nominal discharge current
15 x 8/20 µs impulses
In
5 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
10 kA
Total lightning current
max. total withstand @ 10/350 µs
Itotal
20 kA
Withstand on Combinaison waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
10 kV/5 kA
Withstand on overvoltages IEEE C62.41.1
  10 kV/10 kA
Admissible short-circuit current
Isccr
10000 A
Max. load current
IL
2.5 A
Protection mode(s)
  MC/MD
Protection level
Up
1.5 kV
Protection level CM/DM
@In (8/20µs) and @ 6kV (1.2/50µs)
Up mc/md
1.5 kV/ 1 kV
Protection level L/PE
Up L/PE
1.5 kV
Protection level L/N
for multipolar surge protector
Up L/N
1.5 kV
Mechanical characteristics
Hide details
Technology
  MOV+GDT
Mounting
  on plate
Housing material
  Thermoplastic UL94-V0
Operating temperature
  -40/+85°C
Protection rating
  IP20
Failsafe behavior
  Disconnection and AC line cut-off
Disconnection indicator
  Green Led OFF and AC line cut-off
Voltage/operating indicator
  Green Led ON
Remote signaling of disconnection
  no
Associated disconnection devices
Hide details
Thermal disconnector
  internal
Installation ground fault breaker
  Type `S` or delayed
Standards compliance
Hide details
Standards compliance IEC 61643-11 / EN 61643-11 / UL1449 4ed.